This Gast K882 Repair Kit includes gaskets, filters, and vanes that wear over time. Make sure you have good vacuum and pressure and then turn the unit off again. Rotary Vane Kits to fix Gast 0323, 0523, 0823, 1023, RV03, RV05, AT03, AT05 are available, as well as repair kits for the 0823, 1023, and 1423 models. Unable to add item to List. A link to set a new password will be sent to your email address. Usually, this means the diaphragm is cracked and this is easily replaced. It's important that there are no gaps and that the plate is sitting flush with the rotor housing. Store Home Page | View Cart | Customer Service | Contact Us | Shipping Details | Customer Testimonials
In this case, it is a Gast 1023 Rotary Vane Septic Air Pump. We also carry an extensive line of replacement filters and miscellaneous replacement parts. After you have this bolted on, you will want to do a test run and make sure it is running smooth. This K882 repair kit, sometimes called a rebuild kit, is made by Gast Manufacturing, the original equipment manufacturer. Would love your thoughts, please comment. 11mm socket or 7/16 for the outer housing bolts, 10mm socket or 7/16 for the inner housing bolts, Silicone to hold the gasket in place when placing the outer housing on so you dont have to fight it. : This graphic shows proper vane alignment for your rotary vane compressor. You will need the proper rebuild kit for your pump. You will curse yourself if you do, it doesnt need to be replaced 95 percent of the time. This repair kit, sometimes called a rebuild kit, is made by Gast Manufacturing, the original equipment manufacturer. The Gast compressor repair kit has a diaphragm, head gasket and various other parts that may be needed to get your compressor working again at optimum performance. We use a new razor blade to scrape off the old gasket, ensuring a proper seal. Shopify Theme the largest selection on the web! Fits Gast models 0823-101, 0823-P155, 1023-101 and 1023-V103. Includes the 4 carbon vanes, filters and seals for filters. Razor blade to remove old gasket material as it will be stuck on the metal. Now you can put the outer housing on. We cheat and put a little silicone on where the gasket goes, so it stays in place and we dont have to fight it. Works with Gast AT05 Septic Air Pump. Sometime because of the way the vanes break one will break and the following one will not. All of our Gast Rotary Vane replacement parts and filters are Genuine Gast Replacement parts. After many years of operation, the carbon vanes will wear down or shatter, causing the unit to not lose airflow. Works with Gast AT05 Septic Air Pump. ORDER ONLINE ANYTIME OR CALL OUR SALES STAFF TO PLACE AN ORDER BETWEEN 8:00 AM to 4:30 PM CT MON-FRI TOLL FREE: (877)-925-5132 MOST ORDERS PLACED BEFORE 2 PM CST WILL BE SHIPPED THE SAME DAY, Gast Repair Kit for 0323, 0523, RV03, RV05, AT03, AT05, Gast Rotary Vane Internal Filter Assembly, Gast Rotary Vane External Filter Assembly. , Date First Available It should slowly stop rotating; 2-3 seconds until it stops all the way. It's time consuming and a real pain to get the new one to sit and stay in place. Dieterich, IL 62424, PH: 217-925-5992 TOLL FREE: 1-877-925-5132 FAX: 217-925-5375, Fast and free same day shipping on all gast rotary vane repair parts, need help? 3. We work hard to protect your security and privacy. Rebuild Kit for Gast AT05,AT03 K882 1/4 HP, Air Pump Diaphragm Rebuild Kit Fit for Hiblow Hp-60/Hp-80, Hiblow HP 100LL & 120LL Rebuild Kit (Complete Kit). Includes initial monthly payment and selected options. Copyright 2022 AerationSupply.com Our payment security system encrypts your information during transmission. So, the vane that doesnt break catches the one the one that does and shoves the vanes into the rotating part and jams it. This image shows a correctly installed gasket sealed with DAP. The Model Number is the top number listed under the model heading. : Help others learn more about this product by uploading a video! Once they're all on, you can replace the internal filters and your rotary vane septic air pump is ready to go! Site designed & developed by, if you complete your order in the next 5 minutes, Rebuild Kits FOR Gast Rotary Vane Compressor for 1/4hp, 3/4hp, 1hp, Gast Rotary VaneRotary Vane Air Filter Guard (No Filter), Filter Element FOR RV33 1/4HP Gast Rotary Vane Replacement. This photo shows proper gasket installation on your rebuild Gast Rotary Vane Septic Air Pump. How To Rebuild A Gast Rotary Vane Compressor, Gast 0523 K478 Septic air pump rebuild kit. Each Gast Rotary Vane pump has two of these internal filters. Once your account is created, you'll be logged-in to this account. Once the backing plate is clean, you can put the new gasket on. Gast 0523: Gast 0523 K478 Septic air pump rebuild kit, Gast RV03: Gast RV03 Septic air pump rebuild kit, Gast RV05: Gast RV05 Septic air pump rebuild kit, Gast AT05: Gast AT05 Septic air pump rebuild kit, Gast AT03: Gast AT03 Septic air pump rebuild kit, Gast 0823: Gast 0823 Septic air pump rebuild kit, Gast 1023: Gast 1023 Septic air pump rebuild Kit. Gast rebuilder kits are useful if your compressor has stopped pumping air after several years of service. by Underground It should start right up; you dont have to run it long. You can either rebuild them in place or tank them in the garage and rebuild them; either way is fine. , ASIN We dont share your credit card details with third-party sellers, and we dont sell your information to others. This cartridge filter replacement fits Gast Model 1023 Rotary Vane compressors with an existing filter holder for the AC393. That is just snug. It also analyzed reviews to verify trustworthiness. There was an error retrieving your Wish Lists. Previous page of related Sponsored Products, Is Discontinued By Manufacturer Some pond and lake aerators utilize the GAST rotary vane air compressor and require specific internal and external filters to be cleaned and or replaced routinely to keep them running at optimum performance. . Full content visible, double tap to read brief content. Sometimes you can get it out pretty easily and other times you have to take a hex wrench and loosen the counter face. Return Policy | Warranty & Damage Claims | Privacy Policy | Legal Policies | Site Map, Septic Solutions, Inc.
If the orange spacer gasket is stuck to this plate, do not remove it. There was a problem adding this item to Cart. In addition, rotary vane air compressors, like all air compressors, need to be "rebuilt" on occasion to assist in the longevity and overall performance expected. So just tight, not all your might into it. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. This article will cover how to rebuild a gast rotary vane compressor. Over 850 Septic Products! Your recently viewed items and featured recommendations, Select the department you want to search in. You don't want it to immediately stop. When they do finally need to be serviced, most of them can be rebuilt. One of these items ships sooner than the other. The backing plate gasket will need to be removed. This item can be returned in its original condition for a full refund or replacement within 30 days of receipt. call us toll free at 1-877-925-5132 for expert advice, trust the experts with over 20 years experience in the septic industry, fast and free same day shipping on all gast rotary vane replacement filters, fast and free same day shipping on all gast rotary vane replacement parts, Trust The Experts With Over 25 Years Experience In The Wastewater Industry. Scotch bright will work also. We sometimes sand this down lightly to knock off any rough edges with 600-1000 grit sand paper. It is normally stuck to the metal very well and you will need a razor blade to remove it fully. You will need to remove all of these bolts then gently pull on the plate to remove it. It is meant to run dry with the bearings sealed. Aerobic Septic System is your go-to source for all septic repair and installation information. We've drawn arrows to each of the bolts you will need to remove to replace your Gast Rotary Vane Septic Air Pump damaged carbon vanes. Reviewed in the United States on January 4, 2021. Fits models 0523, 0323, RV03, RV05, AT03, AT05, Fits 0523, 0323, RV03, RV05, AT03, AT05, 0823, 1023, fits gast models 1023 with cartridge filter, ORDER ONLINE ANYTIME OR CALL OUR SALES STAFF TO PLACE AN ORDER BETWEEN 7:30AM & 4:30PM CST M-F, (2) Internal Filters and (2) External Filters. Changing the parts is not complicated and easily done at home with this kit, and is much cheaper than buying a new compressor. For this pump it is 1023-101Q-3G608X. Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. , Manufacturer Start with the center bolt to center it and then put the other bolts in place. LivingWaterAeration.com. This is normally found on top of the unit. You want to first tighten them very slightly, and by that, I mean just so they move a couple millimeters if that. You will need the proper tools to accomplish the rebuild: This is a short list of all the tools you will need to repair your Gast Rotary Vane Septic Air Pump. If you tighten it too much, the counter faceplate and the rotor will touch and bind the pump up. Reliable parts for our lake aerator system. Shipping cost, delivery date, and order total (including tax) shown at checkout. 5-10 seconds is enough. Remove all the bolts. Patriot Pond Pro 6.7 Cubic Feet per Minute Deep Water Subsurface Air & Aeration Roc CANVUNTHY Linear Air Pump AP40 for Pond Aeration, Septic Air Pump, Hydroponic Air P Brief content visible, double tap to read full content. Place the bolts in the housing as to not misplace them. DO NOT SPRAY ANY KIND OF LUBRICANT INTO THE PUMP. Replace the vanes in the slots. UHARBOUR Glycerin Filled Vacuum Pressure Gauge, 2-1/2" Clear dial,1/4"NPT Bottom Co Wehope HP-80 HP-60 Air Pump Rebuild Complete Kit Fit for Hiblow HP 80/HP 60,Includi Autu Parts HP80 AIR Pump Diaphragm Rebuild Repair KIT Fit HP60 80PD000040, HIBLOW HP-100/120 Rebuild Kit - Genuine Factory Certified. [{"displayPrice":"$226.89","priceAmount":226.89,"currencySymbol":"$","integerValue":"226","decimalSeparator":".","fractionalValue":"89","symbolPosition":"left","hasSpace":false,"showFractionalPartIfEmpty":true,"offerListingId":"I24ftyTUWwddn21krsnU%2FEZSRuEseBMEHeA9rjaN7i%2BvRd5sg5B%2B6lu5cXnUcr4vvblXClivnA1z4DHSlu1ez8bkkhf54aYYSACYE1pHPJ1AvFEqe%2BwxcGYHUMvZs0Nz2PrwcRYJivgv2xDTwmeH4IlpAur8B%2Bkaf7HOurmLbhPFh0T6npx8eGAePJmZJznM","locale":"en-US","buyingOptionType":"NEW"}]. DO NOT TRY TO REMOVE THIS, it is a pain to get off and a pain to get to set correctly. : This filter holder and AC393 filter combination will fit all Gast 1023 Rotary Vane pressure air compressors. It's not a car tire, it only needs to be tightened to 115 inch pounds of torque. Whether you're looking for advice, support or tutorials - you've come to the right place! 1-1/4'' Vanes - GENUINE GAST SERVICE KIT! Gast has been known to change model numbers many times, so we use the first 4 digits to identify which pump you have. They are cut a certain way and the vane is also cut in the same way so it should fit flush in the pump. thanks for visiting Septic Solutions! Once it's sitting flush, you can tighten the bolts down. Norex Supply - Save up to 70% on everything! Dap sealant ensures the new gasket adheres effectively, increasing the vacuum and lifetime of your pump. Top subscription boxes right to your door, 1996-2022, Amazon.com, Inc. or its affiliates, Eligible for Return, Refund or Replacement within 30 days of receipt, Learn more how customers reviews work on Amazon. Your all done with the rebuild when your able to screw the bolts back onto the chamber face! Your personal data will be used to support your experience throughout this website and to manage access to your account. You will need to get the internal filters off out of the unit. This rotary vane septic air pump in the picture is not the one being rebuilt, but to show you what to look for a lot, of people give the motor model and that changes every two years or so and doesnt really help. When you login first time using a Social Login button, we collect your account public profile information shared by Social Login provider, based on your privacy settings. Please try again later. See our privacy policy for more information. ${cardName} unavailable for quantities greater than ${maxQuantity}. Septic Solutions carries all available parts needed to rebuild many of the common Gast Rotary Vane compressors. Ships from and sold by Norex Supply - Save up to 70% on everything!. 314 W Center St.
Powered by Shopify, For Sales and Service Call (715) 821-5554, GAST 1/4hp, 3/4hp & 1hp Rotary Vane Rebuild Kits, GAST Rotary Vane Internal Air Filter and Plug, XTREMEAIR Premium Large Pond Aerators With Patended Cabinet, ECONOAIR Large Pond and Lake Aerators & DIY Systems, AIRBOOST Mini Small Pond Aerators With Cabinet, GENAIR Small Pond Aerators Without Cabinet, BEARON Aquatics High Oxygen Transfer Pond Aerators, BEARON Aquatic ICE-EATER Dock Deicing Pumps, BEARON Aquatics WATER-FOWLER Circulating Pumps, RELIANCE Air Compressor Rebuild Kits | Filters | Capacitors, THOMAS Air Compressor Rebuild Kits | Filters | Capacitors, GENAIR Air Compressor Rebuild Kits | Filters, OPTUM Air Compressor Rebuild Kits | Filters, GAST Air Compressor Rebuild Kits | Filters, Natural Pond and Lake Bacterial Additives, Miscellaneous Components | Parts | Equipment, HEAT! You may receive a partial or no refund on used, damaged or materially different returns. Each Gast Rotary Vane pump whose model is listed above has two of these external filters. : Copyright 2017 Septic Solutions, Inc. All rights reserved. Reviewed in the United States on August 10, 2018. Also known as rotary vane septic are pumps, they used on septic systems and are very durable and long-lasting. Gast 1023-101Q-G608NEX Rotary Vane Pump, SSP DBMXD150200 DBMXL120, DBMX150/200 Diaphragm Repair Kit, Gast AT05-520-G215DX Rotary Vane Septic Air Pump, Gast AT05-101-G215DX Rotary Vane Septic Air Pump. If it's stuck to the main counter face leave it as well. Make sure you have good pressure and quickly press and release your finger over the inlet and outlet. Then gently tap on the top and it should come off. Please try again. We're still working on this "Collection", please check back soon. In our experience, and we have rebuilt thousands of these pumps, it is not necessary to remove this. A lot of the HP Gast pumps have an orange spacer gasket inside and it gets stuck to either the end plate or the rotor housing. Installing this repair kit can return the pump to normal functionality. To calculate the overall star rating and percentage breakdown by star, we dont use a simple average. You now are in the heart of the unit where the vanes are. This happens because vanes dont all wear at the same rate; we are talking thousands of an inch. Once you know the model number and have your kit, that we have found for you below by model number, you can rebuild your rotary vane septic air pump. You will need the 11mm socket to achieve this. You will also want to check the lip of it, where it meets up with the rotor housing, to make sure it is clean and will slide on smoothly. Installing this repair kit can return the pump to normal functionality. ${cardName} not available for the seller you chose. To remove the counter face plate, you will need a 10mm socket. We do not have any recommendations at this time. This image shows the bolts removed from the outer casing of your Gast Rotary Vane Septic Air Pump. Trust me Ive done this thousands of times. Next you will remove the outer chamber. Below are air filters and rebuild kits that will aid you in keeping your air compressors running smooth and your fish happy and healthy. We do not sell or give away your data. All Rights Reserved. This repair and rebuild kit fits Gast Manufacturing models: Only logged in customers who have purchased this product may leave a review. Reviewed in the United States on October 29, 2017, Perfect maintenance kit for Gast brand vacuum pump. Gast repair kit K479A for Gast vacuum pumps. The vanes will most likely be shattered and in pieces. Once the gasket is on you can put the counter face back on and put the bolts in with the 10 mm driver. Make sure you put the carbon vanes in correctly, or they will not create a proper vacuum and can jam, ruining your rotary vane septic air pump. Enhancements you chose aren't available for this seller. We also get your email address to automatically create an account for you in our website. It is highly recommended to clean filters every 6 months and replace them once per year. Here, we are going to go through what you need to rebuild a unit and how to check its still viable. After many years of operation, the carbon vanes will wear down or shatter, causing the unit to lose airflow. It is highly recommended to clean filters every 6 months and replace them once per year. You will want to check the inside for carbon pieces and make sure they are all removed. To see our price, add these items to your cart. The oils will destroy the vanes. Please try again. It includes gaskets, filters, and vanes that wear over time. Replaced broken vanes, held onto the filters as I just changed those out recently and know I should change them ever year with my daily use of the Gast 1023 vacuum pump I use with my dairy bucket milker so those filters and seals will get used soon. To add the following enhancements to your purchase, choose a different seller. Is The #1 Reason For Air Compressor Failure. You dont want to just try and undo them, you run the risk of breaking them, as they are hollow.